| 1.1 |
Date updated: |
Jun 09, 2013 |
| 1.2 |
Vessel's name: |
Chembulk Yokohama |
| 1.3 |
IMO number: |
9276248 |
| 1.4 |
Vessel's previous name(s) and date(s) of change: |
Not Applicable |
| 1.5 |
Date delivered: |
Mar 14, 2003 |
| 1.6 |
Builder (where built): |
Usuki Shipyard Co. Ltd., Japan |
| 1.7 |
Flag: |
Singapore |
| 1.8 |
Port of Registry: |
SINGAPORE |
| 1.9 |
Call sign: |
9VFA7 |
| 1.10 |
Vessel's satcom phone number: |
773231821 |
| Vessel's fax number: |
783205531 |
| Vessel's telex number: |
356572413 |
| Vessel's email address: |
cma@esm.amosconnect.com |
| 1.11 |
Type of vessel: |
Chemical/Oil |
| 1.12 |
Type of hull: |
Double Hull |
| 1.13 |
Classification society: |
Det Norske Veritas |
| 1.14 |
Class notation: |
1A1 Tanker for Chemicals and Oil Products ESP |
| 1.15 |
If Classification society changed, name of previous society: |
Bureau Veritas |
| 1.16 |
If Classification society changed, date of change: |
Oct 08, 2010 |
| 1.17 |
IMO type, if applicable: |
2,3 |
| 1.18 |
Does the vessel have ice class? If yes, state what level: |
No , |
| 1.19 |
Date / place of last dry-dock: |
Apr 05, 2013 |
Jiang Yin, China |
| 1.20 |
Date next dry dock due |
Mar 13, 2018 |
| 1.21 |
Date of last special survey / next survey due: |
Apr 05, 2013 |
Mar 13, 2018 |
| 1.22 |
Date of last annual survey: |
|
| 1.23 |
If ship has Condition Assessment Program (CAP), what is the latest overall rating: |
|
| 1.24 |
Does the vessel have a statement of compliance issued under the provisions of the Condition Assessment Scheme (CAS): If yes, what is the expiry date? |
N/A Not Applicable |
| 1.25 |
Length Over All (LOA): |
145.50 m |
| 1.26 |
Length Between Perpendiculars (LBP): |
137 m |
| 1.27 |
Extreme breadth (Beam): |
23.726 m |
| 1.28 |
Moulded depth: |
13.35 m |
| 1.29 |
Keel to Masthead (KTM) / KTM in collapsed condition (if applicable): |
37.58 m |
m |
| 1.30 |
Bow to Center Manifold (BCM) / Stern to Center Manifold (SCM): |
74.14 m |
71.36 m |
| 1.31 |
Distance bridge front to center of manifold: |
43.98 m |
| 1.32 |
Parallel body distances: |
Lightship |
Normal Ballast |
Summer Dwt |
| Forward to mid-point manifold: |
24.52 m |
25.85 m |
25.85 m |
| Aft to mid-point manifold: |
22.71 m |
27.57 m |
32.27 m |
| Parallel body length: |
47.23 m |
53.42 m |
58.12 m |
| 1.33 |
FWA at summer draft / TPC immersion at summer draft: |
227 mm |
29.046 MT |
| 1.34 |
What is the max height of mast above waterline (air draft) |
Full Mast |
Collapsed Mast |
| Lightship: |
35.323 m |
0 m |
| Normal ballast: |
31.928 m |
0 m |
| At loaded summer deadweight: |
27.458 m |
0 m |
| 1.35 |
Net Tonnage: |
6084 |
| 1.36 |
Gross Tonnage / Reduced Gross Tonnage (if applicable): |
11753 |
|
| 1.37 |
Suez Canal Tonnage - Gross (SCGT) / Net (SCNT): |
12214.66 |
10793.19 |
| 1.38 |
Panama Canal Net Tonnage (PCNT): |
9737 |
| 1.39 |
Loadline |
Freeboard |
Draft |
Deadweight |
Displacement |
| Summer: |
3.254 m |
10.122 m |
21181 MT |
26468.0 MT |
| Winter: |
3.465 m |
9.911 m |
20264 MT |
25551.0 MT |
| Tropical: |
3.043 m |
10.333 m |
21470 MT |
26757.0 MT |
| Lightship: |
11.122 m |
2.257 m |
|
5287.0 MT |
| Normal Ballast Condition: |
7.727 m |
5.652 m |
8794.77 MT |
14079.33 MT |
| 1.40 |
Does vessel have multiple SDWT? |
Yes |
| 1.41 |
If yes, what is the maximum assigned deadweight? |
21181 MT |
| 1.42 |
Registered owner - Full style: |
Chembulk Yokohama Pte., Ltd. 120 Lower Delta Road, Cendex Centre, # 08-02 Singapore 169208 Tel: +65 6304 1788 Fax: +65 6220 7988 Telex: Not Applicable Email: operations@bltchembulk.com |
| 1.43 |
Technical operator - Full style: |
Executive Ship Management Pte Ltd Executive Ship Management Pte Ltd
#21-00, 78 Shenton Way
Singapore 079120
Tel: +65-63240500, Ext 12 Fax: +65-63244544 Email: esm@executiveship.com |
| 1.44 |
Commercial operator - Full style: |
Chembulk Management L.L.C. The Delamar 175 Rennell Drive Southport CT 06890 Tel: +1 (203) 682-1700 Fax: +1 (203) 227-0141 Email: operations@bltchembulk.com |
| 1.45 |
Disponent owner - Full style: |
CHEMBULK TRADING II LLC The Delamar 175 Rennell Drive Southport CT 06890 Tel: 203 682-1700 Fax: 203 227-0141 Telex: N/A Email: operations@bltchembulk.com |
| |
| 2.1 |
Safety Equipment Certificate: |
Apr 05, 2013 |
Apr 04, 2014 |
Mar 13, 2018 |
| 2.2 |
Safety Radio Certificate: |
Apr 05, 2013 |
Apr 04, 2014 |
Mar 13, 2018 |
| 2.3 |
Safety Construction Certificate: |
Apr 05, 2013 |
Apr 04, 2014 |
Mar 13, 2018 |
| 2.4 |
Loadline Certificate: |
Apr 05, 2013 |
Apr 04, 2014 |
Mar 13, 2018 |
| 2.5 |
International Oil Pollution Prevention Certificate (IOPPC): |
Apr 05, 2013 |
Apr 04, 2014 |
Mar 13, 2018 |
| 2.6 |
Safety Management Certificate (SMC): |
Feb 01, 2012 |
Not Applicable |
Oct 27, 2016 |
| 2.7 |
Document of Compliance (DOC): |
Dec 17, 2012 |
Oct 25, 2012 |
Nov 04, 2015 |
| 2.8 |
USCG (specify: COC, LOC or COI): COC |
Mar 22, 2012 |
Not Applicable |
Mar 22, 2014 |
| 2.9 |
Civil Liability Convention Certificate (CLC): |
Jan 31, 2013 |
|
Feb 20, 2014 |
| 2.10 |
Civil Liability for Bunker Oil Pollution Damage Convention Certificate (CLBC): |
Jan 31, 2013 |
|
Feb 20, 2014 |
| 2.11 |
U.S. Certificate of Financial Responsibility (COFR): |
Jul 01, 2011 |
|
Jul 01, 2014 |
| 2.12 |
Certificate of Fitness (Chemicals): |
Apr 05, 2011 |
Apr 04, 2014 |
Mar 13, 2018 |
| 2.13 |
Certificate of Fitness (Gas): |
Not Applicable |
Not Applicable |
Not Applicable |
| 2.14 |
Certificate of Class: |
Apr 05, 2013 |
|
Mar 13, 2018 |
| 2.15 |
International Ship Security Certificate (ISSC): |
Feb 01, 2012 |
Not Applicable |
Oct 27, 2016 |
| 2.16 |
International Sewage Pollution Prevention Certificate (ISPPC) |
Apr 05, 2013 |
|
Mar 13, 2018 |
| 2.17 |
International Air Pollution Prevention Certificate (IAPP): |
Apr 05, 2013 |
Apr 04, 2014 |
Mar 13, 2018 |
| 2.18 |
Does vessel have all updated publications as listed in the Vessel Inspection Questionnaire, Chapter 2- Question 2.24, as applicable: |
Yes |
| 2.19 |
Owner warrant that vessel is member of ITOPF and will remain so for the entire duration of this voyage/contract: |
Yes |
| |
| 3.1 |
Nationality of Master: |
Indian |
| 3.2 |
Nationality of Officers: |
Indian |
| 3.3 |
Nationality of Crew: |
Indian |
| 3.4 |
If Officers/Crew employed by a Manning Agency - Full style: |
Officers: EXECUTIVE SHIP MANAGEMENT SAI COMMERCIAL ANNEXEE, 2ND FLOOR, BKS DEVSHI MARG, GOVANDI Tel: +912267551700 Fax: +912267551771 Telex: NOT APPLICABLE Email: crewmumbai@executiveship.com Crew: EXECUTIVE SHIP MANAGEMENT SAI COMMERCIAL ANNEXEE, 2ND FLOOR, BKS DEVSHI MARG, GOVANDI Tel: +912267551700 Fax: +912267551771 Telex: NOT APPLICABLE Email: crewmumbai@executiveship.com |
| 3.5 |
What is the common working language onboard: |
English |
| 3.6 |
Do officers speak and understand English: |
Yes |
| 3.7 |
In case of Flag Of Convenience, is the ITF Special Agreement on board: |
N/A |
| |
| 4.1 |
Can the ship comply with the ICS Helicopter Guidelines: |
N/A |
| 4.2 |
If Yes, state whether winching or landing area provided: |
|
| |
| 5.1 |
Has the vessel Operator submitted a Vessel Spill Response Plan to the US Coast Guard which has been approved by official USCG letter: |
Yes |
| 5.2 |
Qualified individual (QI) - Full style: |
O'Brien's Response Management Inc O'Brien's Response Management Inc
New Jersey Office
103 Morgan Lane,Suite 103
Plainsboro, NJ 08536,USA Tel: +1-985-781-0804 Fax: +1-985-781-0580 Telex: 49617361 OOPS UI Email: commandcenter@obriensrm.com |
| 5.3 |
Oil Spill Response Organization (OSRO) -Full style: |
National Response Corporation(NRC) 3500 Sunrise Highway Suite.T103
Great River, NY 11739, USA
Tel: +1-631-224-9141 Fax: +1-631-224-9086 Email: iocdo@nrcc.com |
| 5.4 |
Has technical operator signed the SCIA / C-TPAT agreement with US customs concerning drug smuggling: |
No |
| |
| 6.1 |
Is vessel fitted with centerline bulkhead in all cargo tanks: |
Yes |
| 6.2 |
If Yes, is bulkhead solid or perforated: |
Solid |
| 6.3 |
Capacity (98%) of each natural segregation with double valve (specify tanks): |
Seg#1: 1282 m3 (2) Seg#2: 2439 m3 (2) Seg#3: 3523 m3 (2) Seg#4: 2337 m3 (2) Seg#5: 1256 m3 (2) Seg#6: 2335 m3 (2) Seg#7: 3779 m3 (2) Seg#8: 2690 m3 (2) Seg#9: 1373 m3 (2) Seg#10: 1169 m3 (2) |
| 6.4 |
Total cubic capacity (98%, excluding slop tanks): |
21012.003 m3 |
| 6.5 |
Slop tank(s) capacity (98%): |
1168.411 m3 |
| 6.6 |
Residual/Retention oil tank(s) capacity (98%), if applicable: |
m3 |
| 6.7 |
Does vessel have Segregated Ballast Tanks (SBT) or Clean Ballast Tanks (CBT): |
SBT |
| 6.8 |
What is total capacity of SBT? |
7322 m3 |
| 6.9 |
What percentage of SDWT can vessel maintain with SBT only: |
37.5 % |
| 6.10 |
Does vessel meet the requirements of MARPOL Annex I Reg 18.2: (previously Reg 13.2) |
Yes |
| 6.11 |
How many grades/products can vessel load/discharge with double valve segregation: |
20 |
| 6.12 |
Maximum loading rate for homogenous cargo per manifold connection: |
250 m3/hr |
| 6.13 |
Maximum loading rate for homogenous cargo loaded simultaneously through all manifolds: |
1000 m3/hr |
| 6.14 |
Are there any cargo tank filling restrictions. If yes, please specify: |
Yes 1.5 Designed Specific Gravity |
| 6.15 |
Pumps: |
No. |
Type |
Capacity |
| Cargo: |
20 |
Centrifugal |
250 M3/HR |
| Stripping: |
|
N/A |
m3/hr |
| Eductors: |
|
N/A |
m3/hr |
| Ballast: |
2 |
Centrifugal |
300 m3/hr |
| 6.16 |
How many cargo pumps can be run simultaneously at full capacity: |
4 |
| 6.17 |
Is ship fitted with a Cargo Control Room (CCR): |
Yes |
| 6.18 |
Can tank innage / ullage be read from the CCR: |
Yes |
| 6.19 |
Can ship operate under closed conditions in accordance with ISGOTT: |
Yes |
| 6.20 |
What type of fixed closed tank gauging system is fitted: |
Floating |
| 6.21 |
Are overfill (high-high) alarms fitted? If Yes, indicate whether to all tanks or partial: |
All tanks |
| 6.22 |
Is a vapor return system (VRS) fitted: |
Yes |
| 6.23 |
Number/size of VRS manifolds (per side): |
2 |
150 mm |
| 6.24 |
State what type of venting system is fitted: |
Independent |
| 6.25 |
Does vessel comply with the latest edition of the OCIMF 'Recommendations for Oil Tanker Manifolds and Associated Equipment': |
Yes |
| 6.26 |
What is the number of cargo connections per side: |
20 |
| 6.27 |
What is the size of cargo connections: |
150 mm |
| 6.28 |
What is the material of the manifold: |
Stainless Steel |
| 6.29 |
Distance between cargo manifold centers: |
380 mm |
| 6.30 |
Distance ships rail to manifold: |
3850 mm |
| 6.31 |
Distance manifold to ships side: |
4000 mm |
| 6.32 |
Top of rail to center of manifold: |
1220 mm |
| 6.33 |
Distance main deck to center of manifold: |
2700 mm |
| 6.34 |
Manifold height above the waterline in normal ballast / at SDWT condition: |
10.36 m |
6.34 m |
| 6.35 |
Number / size reducers: |
4 x 100/150mm (4/6") 2 x 150/200mm (6/8") 2 x 150/250mm (6/10") 2 x 150/300mm (6/12") 1 x 125/150mm (5/6") |
| 6.36 |
Is vessel fitted with a stern manifold: |
No |
| 6.37 |
If stern manifold fitted, state size: |
mm |
| 6.38 |
Type of cargo heating system? |
Steam heating coils |
| 6.39 |
If fitted, are all tanks coiled? |
Yes |
| 6.40 |
If fitted, what is the material of the heating coils: |
Stainless Steel |
| 6.41 |
Maximum temperature cargo can be loaded/maintained: |
80.0 °C / 176.0 °F |
85 °C / 185 °F |
| 6.42 |
Are cargo, ballast and slop tanks coated? |
Coated |
Type |
To What Extent |
| Cargo tanks: |
Yes |
N/A - Stainless Steel 316 L |
Whole Tank |
| Ballast tanks: |
Yes |
Whole Tank |
Good |
| Slop tanks: |
|
|
|
| 6.43 |
If fitted, what type of anodes are used: |
Zinc Anodes |
| |
| 7.1 |
Is an Inert Gas System (IGS) fitted: |
No |
| 7.2 |
Is IGS supplied by flue gas, inert gas (IG) generator and/or nitrogen: |
Nitrogen (Bottled) |
| 7.3 |
Is a Crude Oil Washing (COW) installation fitted: |
N/A |
| |
| 8.1 |
Mooring wires (on drums) |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
|
mm |
|
m |
MT |
| Main deck fwd: |
|
mm |
|
m |
MT |
| Main deck aft: |
|
mm |
|
m |
MT |
| Poop deck: |
|
mm |
|
m |
MT |
| 8.2 |
Wire tails |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
|
mm |
|
m |
MT |
| Main deck fwd: |
|
mm |
|
m |
MT |
| Main deck aft: |
|
mm |
|
m |
MT |
| Poop deck: |
|
mm |
|
m |
MT |
| 8.3 |
Mooring ropes (on drums) |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
4 |
55 mm |
Polyester Combination |
190 m |
43.2 MT |
| Main deck fwd: |
|
mm |
|
m |
MT |
| Main deck aft: |
|
mm |
|
m |
MT |
| Poop deck: |
4 |
55 mm |
Polyestar Combination |
190 m |
43.2 MT |
| 8.4 |
Other mooring lines |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
4 |
55 mm |
Polyestar Combination |
190 m |
43.2 MT |
| Main deck fwd: |
|
mm |
|
m |
MT |
| Main deck aft: |
|
mm |
|
m |
MT |
| Poop deck: |
4 |
55 mm |
Polystar Combination |
190 m |
43.2 MT |
| 8.5 |
Mooring winches |
No. |
# Drums |
Brake Capacity |
| Forecastle: |
2 |
Double Drums |
25.5 MT |
| Main deck fwd: |
|
|
MT |
| Main deck aft: |
|
|
MT |
| Poop deck: |
2 |
Double Drums |
25.5 MT |
| 8.6 |
Mooring bitts |
No. |
SWL |
| Forecastle: |
6 |
70 MT |
| Main deck fwd: |
2 |
70.7 MT |
| Main deck aft: |
2 |
35 MT |
| Poop deck: |
8 |
70 MT |
| 8.7 |
Closed chocks and/or fairleads of enclosed type |
No. |
SWL |
| Forecastle: |
|
MT |
| Main deck fwd: |
|
MT |
| Main deck aft: |
|
MT |
| Poop deck: |
|
MT |
| 8.8 |
Type / SWL of Emergency Towing system forward: |
TK-20F |
100 MT |
| 8.9 |
Type / SWL of Emergency Towing system aft: |
TK-20A |
100 MT |
| 8.10 |
Number of shackles on port cable: |
11 |
| 8.11 |
Number of shackles on starboard cable: |
10 |
| 8.12 |
What is SWL and size of closed chock and/or fairleads of enclosed type on stern: |
70.7 MT |
260x400 |
| 8.13 |
What is SWL of bollard on poopdeck suitable for escort tug: |
70.7 MT |
| 8.14 |
What is brake horse power of bow thruster (if fitted): |
829 bhp |
618.18 Kw |
| 8.15 |
What is brake horse power of stern thruster (if fitted): |
bhp |
0 Kw |
| 8.16 |
Does vessel comply with the latest edition of OCIMF 'Recommendations for Equipment Employed in the Mooring of Vessels at Single Point Moorings (SPM)': |
No |
| 8.17 |
Is vessel fitted with chain stopper(s): |
No |
| 8.18 |
How many chain stopper(s) are fitted: |
0 |
| 8.19 |
State type of chain stopper(s) fitted: |
N/A |
| 8.20 |
Safe Working Load (SWL) of chain stopper(s): |
0 MT |
| 8.21 |
What is the maximum size chain diameter the bow stopper(s) can handle: |
54 mm |
| 8.22 |
Distance between the bow fairlead and chain stopper/bracket: |
0 mm |
| 8.23 |
Is bow chock and/or fairlead of enclosed type of OCIMF recommended size (600mm x 450mm)? If not, give details of size: |
No |
| 8.24 |
Derrick / Crane description (Number, SWL and location): |
Derricks: 1 x 1.5 Tonnes, Cranes: 1 x 5 Tonnes CENTER |
| 8.25 |
What is maximum outreach of cranes / derricks outboard of the ship's side: |
5 m |
| 8.26 |
Does vessel comply with recommendations contained in OCIMF/ICS Ship To Ship Transfer Guide (Petroleum or Liquified Gas, as applicable): |
Yes |
| |
| 9.1 |
What type of fuel is used for main propulsion? |
3500 Sec/RW No.1 |
| 9.2 |
What type of fuel is used in the generating plant? |
C-Oil |
| 9.3 |
Capacity of bunker tanks - IFO and MDO/MGO: |
1086 m3 |
83 m3 0 m3 |
| 9.4 |
Is vessel fitted with fixed or controllable pitch propeller(s)? |
Fixed Pitch |
| 9.5 |
P & I Club - Full Style: |
NORTH OF ENGLAND The Quayside Newcastle Upontyne NEI 3DU UK Tel: +44 (0) 191 2325221 Fax: +44 (0) 191 2610540 Email: general@nepia.com Web: www.nepia.com |
| 9.6 |
P & I Club coverage - pollution liability coverage: |
1000000000 US$ |
| 9.7 |
Date and place of last Port State Control inspection: |
May 21, 2013 / ARATU, BRAZIL |
| 9.8 |
Any outstanding deficiencies as reported by any Port State Control: |
Yes |
| 9.9 |
If yes, provide details: |
ALL DEFICIENCIES RECTIFIED BEFORE DEPARTURE ARATU |
| 9.10 |
Has vessel been involved in a pollution, grounding, serious casualty or collision incident during the past 12 months? If yes, full description: |
Pollution: No , N/A Grounding: No , N/A Serious casualty: No , Collision: No , N/A |
| 9.11 |
Last three cargoes / charterers / voyages (Last / 2nd Last / 3rd Last): |
Contact owner for details |
| 9.12 |
Date/Place of last SIRE Inspection: |
May 29, 2013 / RIO GRANDE |
| 9.13 |
Date/Place of last CDI Inspection: |
May 20, 2013 / ARATU, BRAZIL |
| 9.14 |
Recent Oil company inspections/screenings (To the best of owners knowledge and without guarantee of acceptance for future business)*:
*Blanket "approvals" are no longer given by Oil Majors and ships are accepted for the voyage on a case by case basis. |
Shell, BP |